遥感技术与应用 2015, Vol. 30 Issue (4): 744-756 DOI: 10.11873/j.issn.1004-0323.2015.4.0744 |
图像与数据处理 |
|
|
|
|
23.8 GHz数字相关型全极化微波辐射计的定标及其影响分析 |
王振占1,2,谢莹1,2,3,陆浩1,2,董帅1,2,3,李彬1,2
|
(1.中国科学院国家空间中心微波遥感技术重点实验室,北京 100190;
2.中国科学院国家空间中心,北京 100190;3.中国科学院大学,北京 100049 ) |
|
Calibration and Impact Analysis of 23.8 GHz Digital\|correlation Full-polarimetric Microwave Radiometer |
Wang Zhenzhan1,2,Xie Ying1,2,3,Lu Hao1,2,Dong Shuai1,2,3,Li Bin1,2
|
(1.Key Laboratory of Microwave Remote Sensing Technology,
Chinese Academy of Sciences,Beijing 100190,China;
2.Center for Space Science and Applied Research,Chinese Academy of Sciences,Beijing 100190,China;
3.University of Chinese Academy of Sciences,Beijing 100049,China) |
引用本文:
王振占,谢莹,陆浩,董帅,李彬. 23.8 GHz数字相关型全极化微波辐射计的定标及其影响分析[J]. 遥感技术与应用, 2015, 30(4): 744-756.
Wang Zhenzhan,Xie Ying,Lu Hao,Dong Shuai,Li Bin. Calibration and Impact Analysis of 23.8 GHz Digital\|correlation Full-polarimetric Microwave Radiometer. Remote Sensing Technology and Application, 2015, 30(4): 744-756.
链接本文:
http://www.rsta.ac.cn/CN/10.11873/j.issn.1004-0323.2015.4.0744
或
http://www.rsta.ac.cn/CN/Y2015/V30/I4/744
|
[1]D-uric′A.Development of a Polarimetric Imaging Radiometer System at 91 GHz[D].Bern,Switzerland:University of Bern,2006.[2]Skou N,Laursen B,Sobjaerg S.Polarimetric Radiometer Configurations:Potential Accuracy and Sensitivity[J].IEEE Transactions on Geoscience and Remote Sensing,1999,37(5):2165-71.[3]Thompson A R,d'Addario L R.Frequency Response of a Synthesis Array:Performance Limitations and Design Tolerances[J].Radio Science,1982,17(2):357-69.[4]Liu Jingyi.Research on Problems of Polarimetric Microwave Radio -meter Calibration and Wind Vector Retrieval[D].Beijing:Center for Space Science and Applied Research,Chinese academy of sciences,Beijing,2007.[刘璟怡.全极化微波辐射计定标和风场反演若干问题研究[D].北京:中国科学院空间科学与应用研究中心,2007.][5]Wang Z Z,Zheng W,Liu J Y,et al.A Digital Correlation Full-polarimetric Microwave Radiometer Design and Calibration[C]//IEEE International Geoscience and Remote Sensing Symposium,2012:4688-4690.[6]Lahtinen J,Gasiewski A J,Klein M,et al.A Calibration Method for Fully Polarimetric Microwave Radiometers[J].IEEE Transactions on Geoscience and Remote Sensing,2003,41(3):588-602[7]Lahtinen J,Pihlfyckt J,Mononen K,et al.Fully Polarimetric Microwave Radiometer for Remote Sensing[J].IEEE Transactions on Geoscience and Remote Sensing,2003,41(8):1869-1878.[8]Zhang Yu,Zhang Shengwei.A Design of High Accurate Temperature Measuring System based on Platinum Resistance Transducers[J].Chinese Journal of Sensors and Actuators,2010,23(3):311-314.[张瑜,张升伟.基于铂电阻传感器的高精度温度检测系统设计[J].传感技术学报,2010,23(3):311-314.][9]Huang Yourui,Qu Liguo.The PID Controller Parameter Setting and Implementation[M].Beijing:Science Press,2010.[黄友锐,曲立国.PID控制器参数整定与实现[M].北京:科学出版社,2010.][10]Ulaby F T,Moore R K,Fung A K.Microwave Remote Sensing Volume I:Fundamentals and Radiometry[M].Beijing:Science Press,1988.[乌拉比,穆尔,冯健超.微波遥感(第一卷):微波遥感基础和辐射测量学[M].北京:科学出版社,1988.][11]Lu Hao.Design,Calibration and Error Analysis of Digital-correlation Fully Polarimetric Microwave Radiometer[D].Beijing:University of Chinese Academy of Sciences,2012.[陆浩,数字相关型全极化微波辐射计的研制、定标和误差分析[D].北京:中国科学院大学,2012.] |
|
Viewed |
|
|
|
Full text
|
|
|
|
|
Abstract
|
|
|
|
|
Cited |
|
|
|
|
|
Shared |
|
|
|
|
|
Discussed |
|
|
|
|