Please wait a minute...
img

Wechat

Remote Sensing Technology and Application  2009, Vol. 24 Issue (4): 549-512    DOI: 10.11873/j.issn.1004-0323.2009.4.549
    
Comparative Analysis of On-orbit Calibration between Fully-Polarimetric andConventional Microwave Radiometers
SHI Jian-kang,YAN Wei,PAN Xian-ming,YAN Chao
解放军理工大学气象学院,江苏 南京211101
Download:  PDF (0KB) 
Export:  BibTeX | EndNote (RIS)      
Abstract  

The quality of data measured by microwave radiometer depends on high-accuracy on-orbit calibration.Firstly,two-point calibration scheme for conventional microwave radiometer was described.Secondly,three types of fully polarimetric calibration scheme including external calibration,internal calibration and hybrid calibration scheme were analyzed in terms of on-orbit application.Lastly,a comparative analysis of on-orbit calibration was presented between fully polarimetric and conventional radiometer in terms of calibration equation,calibration error and calibration accuracy.

Key words:  Microwave radiometer      Fully polarimetric      On-orbit calibration      Calibration equation      Calibration error     
Received:  22 September 2008      Published:  29 November 2010
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors

Cite this article: 

SHI Jian-kang,YAN Wei,PAN Xian-ming,YAN Chao. Comparative Analysis of On-orbit Calibration between Fully-Polarimetric andConventional Microwave Radiometers. Remote Sensing Technology and Application, 2009, 24(4): 549-512.

URL: 

http://www.rsta.ac.cn/EN/10.11873/j.issn.1004-0323.2009.4.549     OR     http://www.rsta.ac.cn/EN/Y2009/V24/I4/549

[1]  Xiao Zhihui,Zhang Zuyin,Guo Wei.A Review:The Calibration of Ground-based,Airborne and Satellite-borne Microwave Radiometers (in Chinese)[J].Remote Sensing Technology and Application,2000,15(2):113-120.[肖志辉,张祖荫,郭伟.地基、空基、星基微波辐射计定标技术概览[J].遥感技术与应用,2000,15(2):113-120.]
 [2] Lu Ying,Zhang Zuyin,Guo Wei,et al.Periodic Calibration of Spaceborne Microwave Radiometer-A Review (in Chinese) [J].Journal of Electronics,1997,19(5):695-700.[吕颖,张祖荫,郭伟,等.星载微波辐射计周期定标技术的综述[J].电子科学学刊,1997,19(5):695-700.]
 [3] Lahtinen J,Pihlflyckt J,Mononen I,et al.Fully Polarimetric Microwave Radiometer for Remote Sensing[J].IEEE Transactions on Geoscience and Remote Sensing,2003,41(8):1869-1878.
 [4] Lahtinen J,Hallikainen M T.Hut Fully Polarimetric Calibration Standard for Microwave Radiometry[J].IEEE Transaction on Geoscience and Remote Sensing,2003,41(3):603-611.
 [5] Lahtinen J,Gasiewski A J,Klein M,et al.A Calibration Me-thod for Fully Polarimetric Microwave Radiometers[D].PH.D.:Helsinki University of Technology,2002.
 [6] Ruf C S, Li J.A Correlated Noise Calibration Standard for Interferometric,Polarimetric,and Autocorrelation Microwave Radiometers[J].IEEE Transactions on Geoscience and Remote Sensing,2003,41(10):2187-2196.
 [7] Corbella I,Gasiewski A J,Klein V L M,et al.On-board Accurate Calibration of Dual-channel Radiometers Using Internal and External References[J].IEEE Transaction on Microwave Theory and Tech,2002,50(7):1816-1820.
 [8] Chen Wenxin.On-orbit Calibration of Microwave Radiometer (in Chinese) [C].2000.[陈文新.微波辐射计星载定标方法[C].空间电子学年会论文集,2000.]
 [9] Wentz F J,Meissner T.Amsr Ocean Algorithm Theoretical Basis Document,Version 2[R].Santa Rosa,USA:Remote Sensing Systems,2000.

10 Gaiser P W,Twarog E M.The Windsat Space Borne Polarimetric Microwave Radiometer:Sensor Description and Mission OverviewR.Washington DC,USA:Naval Research Laboratory,2004.371-374.